Distributed alarms


The following procedure describes making alarms active with change values.

To activate distributed alarms

  1. To add an alarm for monitoring, in Target mode, type ALRMDIST on the COMMAND line, and press Enter.The ALRMDST view is displayed, as shown below:

    COMMAND  ===>                                                                       
     CURR WIN ===> 1        ALT WIN ===>                                                 
      W1 =ALRMDIST==========S9Q1=====*========01APR2025==12:40:47====MVMQS====U===18=====
     + Distributed Alarms                                 + Show Fixed Section           
     CMD Alarm          Library    Group      Description                                
     --- Name--------   ---------- ---------- ------------                               
     ADD BBSBFP01       BOLTSM4    MVMQS      MVMQS: Buffer Pools Usage                  
         BBSCHI01       BOLTSM4    MVMQS      MVMQS: CHINIT and TCP Listener Status      
         BBSCHL01       BOLTSM4    MVMQS      MVMQS: CHANNELs Status                     
         BBSCOF01       BOLTSM4    MVMQS      MVMQS: CF Sturcture Usage                  
         BBSDLQ01       BOLTSM4    MVMQS      MVMQS: no DLQ or message(s)in the DLQ      
         BBSDLQ02       BOLTSM4    MVMQS      MVMQS: Reply queues with max depth in LQ   
         BBSLOG01       BOLTSM4    MVMQS      MVMQS: Output Log Buffer Utilization       
         BBSLOG02       BOLTSM4    MVMQS      MVMQS: Logging Status and Availability     
         BBSMGR00       BOLTSM4    MVMQS      MVMQS: Local QMGR Status(Low overhead)     
         BBSMGR02       BOLTSM4    MVMQS      MVMQS: QMGR and Components Status          
         BBSPGS02       BOLTSM4    MVMQS      MVMQS: PageSet Free Space                  
         BBSQGS02       BOLTSM4    MVMQS      MVMQS: Sharing Group Connection Status     
         BBSQST01       BOLTSM4    MVMQS      MVMQS: No MQGET and Messages on Queue      
         BBSQST02       BOLTSM4    MVMQS      MVMQS: No MQGET in a timely manner         
         BBSQUE01       BOLTSM4    MVMQS      MVMQS: Queue Depth High or Full            
         BBSQUE02       BOLTSM4    MVMQS      MVMQS: Transmission Queues not depleting   
         BBSTHD02       BOLTSM4    MVMQS      MVMQS: Indoubt Threads                     
         BBSTPL02       BOLTSM4    MVMQS      MVMQS: Topology Exception    
  2. Type Add in the CMD field next to the Alarm Name that you want to monitor, and press Enter.
  3. Press F3 until you reach the Selection Menu as shown below:

    -------------------------- BMC AMI Ops Selection Menu ------------ ENTER OPTION
    OPTION  ===>                                               DATE   -- 2020/09/03
                                                                TIME   -- 07:37:32  
           0    Parameters and Options                          USERID -- BOLTSM1   
           1    Administration                                  MODE   -- ISPF 7.3  
           E    Alerts and Alarms                                                   
           P    PLEX Management (PLEXMGR)                                           
           U    Utilities, Tools, and Messages                                      
        Solutions for:                                                              
           A    Automated Operations                                                
           C    CICS                                                                
           D    Db2                                                                 
           I    IMS                                                                 
           J    JAVA Environments                                                   
           L    Linux and z/VM                                                      
           N    Network Management                                                  
           O    Cost Optimization                                                   
           S    Storage Management                                                  
           T    Application Management and Performance Tuning                       
           W    MQ                                                           
           Z    z/OS and USS                                                        
                                                                                   
           Enter X to Terminate                                                     
                        w Copyright 1991-2021 BMC Software, Inc.                                                                             
  4. On the Selection Menu, select option E-Alerts and AlarmsThe ALARM view is displayed, as shown below:

    ----------------------------- Alerts and Alarms------------------------------
    OPTION  ===>                                               DATE   -- YYYY/MM/DD
                                                               TIME   -- 14:22:31
          1  ALERTS       Alert Management                     USERID -- MVSLPW1
          2  ALARMS       Alarm Administration (MVALARM)       MODE   -- ISPF 6.0
          3  ALARMS       Integrated Alarm Administration (PLEXMGR)              
                                                                                
          M  MESSAGES     Messages and Codes
  5. Select option 3, ALARMS Integrated Alarm Administration (PLEXMGR).The EZALARMS view is displayed, as shown below:

    COMMAND  ===>                                                 SCROLL ===> PAGE
    CURR WIN ===> 1        ALT WIN ===>                                            
     W1 =EZALARMS==========ESAJ=====*========DDMMMYYYY==14:25:30====PLEXMGR==D====1
                                Alarm Management                              
      Alarm Definition Lists                            Alarm Reports         
    . By Name                +----------------------+ . Current By Severity   
    . By Library             |   Place cursor on    | . Current By Name       
    . By Group               |    menu item and     | . Current by Target     
    . By Product             |     press ENTER      | . Current by Product    
    . By Target (Context)    +----------------------+ . Summarized by Severity
    . Active Alarms                                   . Alarm Report Log      
    . Migrated Alarms                                 . Alarm Activity        
    . Summary by Group                                                        
                                                                             
      Modification Log        Status and Performance    Other                 
    . Alarm Modifications    . Alarm Evaluator Status . Alarm Parameters      
    . Alarm Parm Actions     . Alarm Performance      > MVAlarm 2.1           
                                                      > MVAlert
                                                      . Deployment Requests
  6. Select an option from the Alarm Definition Lists, or invoke the AMD view to display the configured alarms, as shown below:
    COMMAND  ===>
     CURR WIN ===> 1        ALT WIN ===>
     >W1 =AMD===============BLAHTM71=*========04APR2025==10:47:52====PLEXMGR==D===47=================
    CMD Alarm            Group    Library  Admin     Freq Description                       Product  
     --- Name--------     Name---- Name---- Status--- /Sec -----------                       --------
    ACT BBSDLQ02         MVMQS    BOLTSM2             900 Local Queues Overview             MVMQS    
         BBSMGR01         MVMQS    ACTIVE   NoTarg      60 MVMQS: QMGR and Components Status MVMQS   
         BEN@MQEGET@2     DEFAULT  INACTIVE             60 Detailed Stats Get                MVMQS   
         BEN@WFSTATS2     DEFAULT  INACTIVE             10 Detailed Stats Workflow           MVMQS   
  7. Review the configured alarm and modify as required for your installation and then Activate the alarm by using the ACT line command. 

(BMC.AMIOPSMQ.SPE2507)

 