This documentation applies to the 8.1 version of BMC Atrium Core, which is in "End of Version Support." You will not be able to leave comments.

To view the latest version, select the version from the Product version menu.

Viewing job run details of jobs created in Atrium Integrator Spoon in Atrium Integrator console

When you create a job in Atrium Integrator Spoon and try to open in Atrium Integrator console you need to update the logging details for the transformation and job to view the job run details.

To view job runs details of jobs created in Atrium Integrator Spoon in Atrium Integrator console

  1. To update the logging options for the transformation:
    1. Right-click the transformation on the left panel.
    2. Select Settings > Logging tab.
      • In the Log Connection field select the name of the connection that you have logged in through BMC Atrium Integrator Spoon.
      • In the Log table name field enter the name of the table (UDM:TransformationLog) in which the logs are stored.
      • In the Fields to log area select the list of fields for which you want to enable logging.
      • In the Step name field, select the step
        • In the Line input field select the source step.
        • In the Line read field select the source step.
        • In the Line update, Line return, and Line output field select the output step name.
        • In the Line rejected field select the output step name.
  2. To update the logging options for the steps, click the Step on the left panel.
    • In the Log Connection field select the host name of the BMC Remedy AR System database.
    • In the Log table name field select the name of the table (UDM:StepLog) in which the logs are stored.
    • In the Fields to log area select the list of fields for which you want to enable logging.
  3. To update the logging options for the job:
    1. Right-click the job on the left panel.
    2. Select Settings > Logging tab.
      • In the Log Connection field select the name of the connection that you have logged in through BMC Atrium Integrator Spoon.
      • In the Log table name field enter the name of the table (UDM:JobLog) in which the logs are stored.
      • In Fields to log area select the list of fields for which you want to enable logging.
  4. To update the logging options for the job entry, click Job Entry on the left panel.
    • In Log Connection field select the host name of the BMC Remedy AR System database.
    • In Log table name field select the name of the table (UDM:JobEntryLog) in which the logs are stored.
    • In Fields to log area select the list of fields for which you want to enable logging.

This version of the documentation is no longer supported. However, the documentation is available for your convenience. You will not be able to leave comments.

Comments

  1. Jan Sierens

    'In the Line rejected field select the error logging step name.'

    I think this statement is wrong. It should also be the output step as it will count the number of lines rejected by the specified step.

    In the examples: LINES_READ and LINES_WRITTEN are mapped to the source step and all others are mapped to the output step.

    Jan 19, 2018 09:45
    1. Chaitanya vikas Ghanta

      Hello Jan,

      I will discuss your query with the SME and write back to you.

      Regards,

      Chaitanya

      Jan 22, 2018 03:06
    1. Kanchana Iyer

      Hello Jan,

      Thanks for pointing this out. This sentence has been fixed to read "In the Line rejected field select the output step name."

      Jun 26, 2018 11:44