Upgrading IT Data Analytics in a multiple server environment silently
Where you are in the Upgrade process
The page .Upgrading IT Data Analytics in a single server environment using the wizard v11.3.01 was not found -- Please check/update the page name used in the MultiExcerpt-Include macro
You can upgrade IT Data Analytics in a multiple server environment, silently, by doing a custom upgrade. The silent upgrade obtains the required user inputs from the options files. You can download sample options files from within the procedure below, or you can generate them.
To perform a custom upgrade silently
Do the following:
Log in to the host computer on which you want to upgrade IT Data Analytics, and delete all the files from the temporary directory:
- (Windows) %temp%
(Linux) /tmp
Extract the downloaded files (the installer) to a temporary location outside the following location to avoid any file sharing conflicts.
(Windows) C:\Program Files
(Linux) /opt
It is strongly recommended that you exit all programs before starting the installation.
From the command prompt, navigate to the Disk1 folder:
- (Windows) <DownloadLocation>\BMC-TrueSight-IT-Data-Analytics\Disk1\
- (Linux) <DownloadLocation>/BMC-TrueSight-IT-Data-Analytics/Disk1/
Download the following sample options files depending on the component that you want to upgrade and your environment, or generate one. To generate the file, go to Step 6.
Component Windows Sample Options file Linux Sample Options file Indexer Search Server Configuration Database Search Collection Station Console Server Copy the sample options file to the following folder on every computer where you want to upgrade the components:
- (Windows) C:\Program Files\BMC Software\TrueSight\ITDA
- (Linux) /opt/bmc/TrueSight/ITDA
To install the product in a different location, change the value of the
installLocation
property in the options file.Run the following command to generate the options file:
From the command prompt, run the following command to generate the options file:
(Windows)
setup.exe –DGENERATE_OPTIONS_FILE=pathToOptionsFile
(Linux) As a non-root user, run
setup.bin –DGENERATE_OPTIONS_FILE=pathToOptionsFile
Note
pathToOptionsFile
must contain the name of the options file. If the file name or path includes a space, enclose the path and name in double quotes.
Examples:
(Windows - path with space)
setup.exe –DGENERATE_OPTIONS_FILE="C:\temp folder\Disk1\options File.txt"
(Linux - path with space)
setup.bin –DGENERATE_OPTIONS_FILE="opt/temp folder/Disk1/options File.txt"
- This command launches the TrueSight IT Data Analytics installation wizard. You must complete the wizard-based installation once, to populate the options file with properties. Your options file is then ready to be used in silent installation.
- You will need to type the Remedy Single Sign-On password in an encrypted form in the options file in Step 8. Encrypt this password using the EncryptPWD utility:
- Open the EncryptPWD utility by navigating to:
- (Windows) <DownloadLocation>\BMC-TrueSight-IT-Data-Analytics\Disk1\utility\EncryptPWD
- (Linux) <DownloadLocation>/BMC-TrueSight-IT-Data-Analytics/Disk1/utility/EncryptPWD
- Run the tool, and click the Encrypt tab.
- Type the password, confirm it, and click Encrypt.
- Note down the encrypted password (from the Encrypted Password field)
- Open the EncryptPWD utility by navigating to:
Open and edit the options file. You can either retain the default values for the properties or change them, and save the file. The options file defines the installation properties in the form of a prefix tag followed by a property name and value pair.
Run the following command to start the silent installation. Type the complete path to the options file in the command. If the path includes a blank space, enclose the path within double quotes.
(Windows) setup.exe -silent -DOPTIONS_FILE=
"<
path_to_itda_silent_options_file>"
(Linux) ./setup.bin -silent -DOPTIONS_FILE=
"<
path_to_itda_silent_options_file>"
The installation may take up to 10 minutes. After the installation is complete, the Installation Summary page is displayed.
You can periodically check the installation status by checking the itda_install_log.txt file located at:
- (Windows)%temp%
(Linux) /tmp
Search for the following log message in the itda_install_log.txt file to ensure that TrueSight IT Data Analytics is installed successfully:
BMC
TrueSight IT Data Analytics 11.3.01 install succeeded
The following environment variable points to the IT Data Analytics installation path after the upgrade.
(Windows) %BMC_ITDA_HOME%
(Linux) $BMC_ITDA_HOME
Run the following command to verify the TrueSight IT Data Analytics status:
- (Windows) Navigate to the TrueSight\ITDA\bin directory, and run
run.bat -status
command. - (Linux) Navigate to the TrueSight/ITDA/bin directory, and run
./run.sh -status
command.
A list of IT Data Analytics services are displayed as shown in the following example:
TrueSight IT Data Analytics Indexer:
The requested service has already been started.
TrueSight IT Data Analytics ConfigDB:
The requested service has already been started.
TrueSight IT Data Analytics Server:
The requested service has already been started.
TrueSight IT Data Analytics Collection Station:
The requested service has already been started.- (Windows) Navigate to the TrueSight\ITDA\bin directory, and run
- (Optional) Start using Remedy Single Sign-On as your authentication mechanism by running the
enablesso CLI command
. Using Remedy Single Sign-On is required if you plan to use TrueSight IT Data Analytics in conjunction with the TrueSight products
For more information, see User authentication options.
(Optional) If you are upgrading from TrueSight IT Data Analyticsversion 2.7, ensure that you modify the properties for re-indexing after upgrading.
Restore the backed up keystore file (bmcitda.jks), and restart the IT Data Analytics server after upgrading.
Note: The bmcitda.jks keystore file is backed up before upgrading to ensure that the custom certificates are not lost after upgrading.
The page .Upgrading IT Data Analytics in a single server environment using the wizard v11.3.01 was not found -- Please check/update the page name used in the MultiExcerpt-Include macro
Comments
Log in or register to comment.