Sizing charts and guidelines for data and event management environments

The following tables provide sizing summaries for an environment that incorporates both data collection and event management:

Provided values represent the maximum values recommended for the tested parameter.

Sizing chart for data collection of the TrueSight Infrastructure Management Server

Characteristic

Small environment

Medium environment

Large environment

Number of devices

5000

10,000

20,000

Total number of attributes

300,000

600,000

1,700,000

Total number of monitor instances on the BMC TrueSight Infrastructure Management Server

30,000

60,000

250,000

Duration of raw data retention

3 days

3 days

3 days

Duration of rate retention

3 months

3 months

3 months

Number of groups

1000

2000

3000

Number of SLOs

20

40

60

Sizing chart for event management of the TrueSight Infrastructure Management Server

Characteristic

Small environment

Medium environment

Large environment

Number of intelligent events per day 1

10,000

20,000

40,000

Number of external events per day 1

60,000

200,000

350,000

Number of remote cells

0

5

10

Duration of event retention2

default

default

default


 1 Rate is based on events that are evenly distributed in a day.

 2 To view the default value, edit the mcell.conf file.

Sizing chart for data collection of the Integration Service

CharacteristicSmall environmentMedium environmentLarge environment
Maximum number of monitor instances per Integration Service30,00060,000250,000
Number of Integration Services111
Maximum number of PATROL Agents500900900

Sizing chart for multiple Integration Services running on the same Integration Service host

When multiple Integration Services are running on the same Integration Service host computer, the following sizing chart represents the data for those multiple Integration Services. Each Integration Service process requires 4 GB of memory.

Characteristic

Small environment

Medium environment

Large environment

Number of devices

5000

10,000

20,000

Total number of attributes

300,000

600,000

1,700,000

Total number of monitor instances on the BMC TrueSight Infrastructure Management Server

30,000

60,000

250,000

Duration of raw data retention

3 days

3 days

3 days

Duration of rate retention

3 months

3 months

3 months

Number of groups

1000

2000

3000

Number of SLOs

20

40

60

Maximum number of PATROL Agents that can be connected to each of the Integration Service900900900

Note

When the load of the TrueSight Infrastructure Management Server is distributed among Integration Services, BMC recommends a maximum of three Integration Services instances running on a single Integration Service host computer.

Sizing chart for Infrastructure Management consoles

Characteristic

Small environment

Medium environment

Large environment

Concurrent number of users—operator console

25

50

100

Concurrent number of users—administration console

1

1

1