Facilities entities and metrics
This topic contains the following sections:
Specific types
Icon | System name | Description |
---|---|---|
Facility | A system that represents a Datacenter facility (e.g a rack or a line) | |
Facility - Line | A system that represents a line. | |
Facility - Rack | A system that represents a rack. | |
Facility - Room | A system that represents a room. | |
Facility Device - Air Conditioner | A system that represents an air conditioner. | |
Facility Device - PDU | A system that represents a Power Distribution Unit. | |
Facility Device - UPS | A system that represents a Power source back-up. |
Icon | Workload name | Description |
---|---|---|
Facility Generic workload | A workload measurement about a Facility equipment. |
Datasets
Dataset name | Description |
---|---|
SYSENV | Environment metrics |
SYSPWR | System Power facilities |
Metrics
Dataset name | Metric name | Description |
---|---|---|
SYSENV | BYCOMP_STATUS | On/Off status of compressor |
SYSENV | COLD_AISLE_AIRFLW_FT_MIN | Cold aisle airflow in feet per minute |
SYSENV | COLD_AISLE_AIRFLW_M_SEC | Cold aisle airflow in meter per sec |
SYSENV | COLD_AISLE_HUMIDITY | Cold aisle humidity in RH% |
SYSENV | COLD_AISLE_TEMP_C | Cold aisle temperature in Celsius |
SYSENV | COLD_AISLE_TEMP_F | Cold aisle temperature in Fahrenheit |
SYSENV | HOT_AISLE_TEMP_C | Hot aisle temperature in Celsius |
SYSENV | HOT_AISLE_TEMP_F | Hot aisle temperature in Fahrenheit |
SYSENV | IN_HUMIDITY | Input relative humidity of facility device |
SYSENV | IN_TEMP_C | Input temperature of facility device in Celsius |
SYSENV | IN_TEMP_F | Input temperature of facility device in Fahrenheit |
SYSENV | OUT_HUMIDITY | Output relative humidity of facility device |
SYSENV | OUT_TEMP_C | Output temperature of facility device in Celsius |
SYSENV | OUT_TEMP_F | Output temperature of facility device in Fahrenheit |
SYSPWR | BYPHASE_PWR_UTIL | Power Utilization by Phase |
SYSPWR | BYSET_AMPERAGE_MAX | Maximum line amperage by Set |
SYSPWR | BYSET_AMPERAGE_UTIL | Average amperage reading by Set |
SYSPWR | BYSET_AMPERAGE_UTIL_PEAK | Peak amperage reading by Set |
SYSPWR | BYSET_POLES | Number of line poles by Set |
SYSPWR | BYSET_PWR_CONSUMPTION | Energy Consumption by Set |
SYSPWR | BYSET_PWR_UTIL | Power Utilization by Set |
SYSPWR | BYSET_VOLTAGE | Line voltage by Set |
SYSPWR | PWR_AVAILABLE | Available Power |
SYSPWR | PWR_IDLE | Power Utilization in idle |
SYSPWR | PWR_MAX | Maximum Power |
SYSPWR | PWR_UTIL | Power Utilization |
SYSPWR | PWR_UTIL_PERC | Percentage Power Utilization |
Analysis templates
Group | Name | Description |
---|---|---|
Facilities | Power Utilization - Used vs Maximum | Shows the power utilization for facilities over time; for each facility maximum available and used power are shown. |
Facilities | Power Utilization Analysis - Stacked | Shows the power utilization analysis for facilities over time; all sub-resources are shown on a stacked chart. |
Facilities | Power Utilization Analysis | Shows the power utilization analysis for facilities over time; all sub-resources are shown in the same chart. |
Facilities | Power Utilization Overview | Shows the power utilization overview for facilities on a summary pie chart. |
Hierarchy templates
Name | Description |
---|---|
Facility Solution - CRAC Power from Compressors | Generates CRAC Power Util from Compressors Power Util |
Facility Solution - Line from Rack | Generates Line Power Utilization from Rack data. |
Facility Solution - Rack from PDU | Generates Rack Power Utilization from PDU data. |
Facility Solution - Room from line | Generates Room Environmental Metrics from Line data. |
Facility Solution - Room from UPS/AC | Generates Room Power Metrics from UPS and AC data. |
Facility Solution - UPS Power from Phases | Generates UPS Power Util from Phases. |