Configuring the event buffer

If the PATROL Agent loses the connection to BMC Helix Operations Management, it will continue buffering events in its cache. After the connection is reestablished, the PATROL Agent will send the cached events to BMC Helix Operations Management.

The time period for which the events are cached is configured using a pconfig variable:

/AgentSetup/bemBufferKeepWait 

Refer the following table to set the event buffering duration:

ConsiderationValue
Unit usedMinutes
Minimum value15
Maximum value1440
Default value60