COS variables

In the PATROL Agent Configuration Utility, these variables are located in /AgentSetup/cos.


/AgentSetup/cos variables

Variable

Description

Format

For information, see page

_name_

COS name

Text string (cos)

Cannot be changed

_type_

COS type

Text string (DATA_ REPOSITORY)

Cannot be changed

flowControlBufferThreshold

Limit at which the process will start sending messages out anyway

Numeric

Not applicable

flowControlWindowMinSize

Minimum number of messages between acknowledgements

3.5 agent only

Numeric

Not applicable

flowControlWindowMaxSize

Maximum number of messages between acknowledgements

3.5 agent only

Numeric

Not applicable

flowControlWindowSize

Number of messages between acknowledgements

3.6 agent only

Numeric

Not applicable

messageCacheMaxMessages

Maximum number of messages to be cached for a single System Output Window before they are flushed to the PATROL Console

Default is 10

Mumeric

Not applicable

messageCacheTimerInterval

Maximum amount of time a cached message will stay on the agent. This does not mean a message has to be on the agent this long. As soon as any message enters the cache, this timer is activated. If the timer gets a chance to go off, then every single console's cache will be flushed when it does

Default is 10

Seconds

Not applicable