Editing external Java collector process settings

The Java collector is pre-configured with default values, so the Java collector functions the moment an Entuity server instance is added. You can edit and make changes to these values.

  1. From the PATROL Console work area, right-click Entuity.
  2. Select KM Commands > PATROL KM Administration > Advanced > External Java Collector Process Settings.
    The External Java collector process settings dialog box is displayed.
  3. Change one or more of the settings listed below.
  4. Click Ok.

Setting

Description

Default Value

Timeout (sec)


Connection

Timeout (seconds) if a connection is not opened in the defined time.

60 sec


Command

Timeout (seconds) if no response is received in the defined time.

60 sec

Connection Pool

(Not available in this release)

Min

Minimum number of connections permitted for each configured Entuity server.

NA

Max

Maximum number of connections permitted for each configured Entuity server

NA

Debug

Enable to commence debug and create a debug file.

Disabled

Debug file name

You can use the default file name or enter a new name. After changing the file name, you must restart the Java collector.

%PATROL_HOME%\ZXC_JavaCollector.txt.

Thread Pool

Min

Minimum number of threads created for the Java collector process.

100

Max

Maximum number of threads created for the Java collector process.

1000

Retrieve default settings

Use to revert all settings to the default values.

Disabled

Restart the external Java collector process

When enabled, the external Java process is restarted if changes are made to the configuration.

Enabled

Was this page helpful? Yes No Submitting... Thank you