Configuration parameters for retrieving synthetic execution data

When you configure the APM monitoring profile in PATROL for Application Management v10.7.00, you manually configure the AM Configuration monitor type. To do this, fill out the following fields.

Note

If your Execution Plan interval is set to two minutes or less, the first few results may not be visible.

Configuring the AM Configuration monitor type

FieldInstructions
TrueSight Presentation Server Configuration
Host NameEnter the Presentation Server name or IP address. This is a required field.
ProtocolSelect HTTPS or HTTP.
Port
Enter a port for the Console. The default value is 443. This is a required field.
TenantEnter the tenant name. The default value is BmcRealm. This is a required field.
UserEnter the user name.
PasswordEnter the user's password.
Object instance format

Select ID or Name to configure how object instances are displayed. The default value is ID.

The monitor's history is not maintained if you switch between the ID and Name formats.

Admin Configuration
Java Home Location

Enter the path to the Java home directory. This must be version 1.7 or above. This is a required field.

Initial Heap Size (MB)Initial size of Java heap memory, measured in megabytes. The default is 64 MB.
Max Heap Size (MB)Maximum size of Java heap memory, measured in megabytes. The default is 128 MB.