Limited support

   

BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.

BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Batch Optimizer (Advanced and Standard) 2.9.

Stopping the BMC Software Primary Subsystem2

BMC recommends that the BMCP run continuously.

However, you must stop it as part of an orderly shutdown of MVS before an IPL. The SHUTDOWN command provides a nondisruptive way of stopping a BMC Software Primary Subsystem, allowing jobs to finish before the subsystem shuts down.

To stop the BMCP

  1. Enter the following command:

    bmcp SHUTDOWN

    The BMCP responds with message BMC10106I to indicate that termination was initiated and message BMC10228I to indicate that termination completed. Status messages are also displayed.

    The following are example messages:

    BMC10106I Subsystem termination initiated. BMCP

    BMC10228I Subsystem termination completed. BMCP

  2. (optional) Review the system log to ensure that the command is completed successfully.

Was this page helpful? Yes No Submitting... Thank you