Reloading the Job Optimizer Pipes Subsystem initialization parameters

Use this procedure to reload the Job Optimizer Pipes Subsystem initialization parameters. These parameters are defined in member PIPPRMxx that is pointed to by the BatchPlex member PIPEPARMS parameter, and can be reloaded while the Job Optimizer Pipes Subsystem is active.

To reload Job Optimizer Pipes Subsystem initialization parameters

Enter the following command:

F MBOP,RELOAD PARM=INSTPARM[,SCOPE=LOCAL|GLOBAL]

When the reload is performed by the Job Optimizer Pipes Subsystem, the following message is displayed on the console:

BMC282108I JOB OPTIMIZER PIPES RELOAD INSTPARM ENDED. RC=returnCode

Changes to the following parameters take effect immediately following command execution:

  • Operation Mode (OPERMODE)

  • Tasks Sleeping Interval (INTERVAL)

  • SMF Recording (SMFREC)

  • Accept Additional Readers (ADD-RDRS)

  • Accept Additional Writers (ADD-WTRS)

  • Security Interface (SECURITY)

  • IBM BatchPipes Subsystem IDs (BPSUBSYS)

Changes to other parameters do not affect the current execution of the Job Optimizer Pipes Subsystem and require stopping and restarting of the Job Optimizer Pipes address space.