Displaying the status of the BMC Software Primary Subsystem

After you see message BMC10100I in the system log, you can display the status of the BMCP to determine whether the subsystem is active. Each MVS image can have only one BMCP active.

To display the status of the BMCP

  1. Enter the following command:

    bmcp STATUS

    The BMCP responds with message BMC10700I to indicate the status of the BMCP. An example follows:

    BMC10700I STATUS,SUBSYSTEM ASID(0032) IS ACTIVE BMCP

  2. (optional) Review the system log to ensure that the command completed successfully.