Stopping the MainView Batch Optimizer Subsystem - Job Optimizer
You can leave the MBOS running continuously. However, you must stop it as part of an orderly shutdown of MVS before an IPL.
To stop the MBOS address space in a nondestructive manner
Enter the following command:
mbos SHUTDOWN
When you stop the MBOS, the following actions occur:
The MBOS responds with message BMC11106I to indicate that termination was initiated and message BMC11228I to indicate that termination completed. The following messages are examples:
If Job Optimizer has work executing on the subsystem at the time the SHUTDOWN command is entered, the MainView Batch Optimizer Subsystem issues the BSL QUIESCE NOW command to perform an orderly shutdown.
The MBOS remains in memory until you perform an IPL.
(optional) To stop the MainView Batch Optimizer Subsystem address space immediately regardless of any processing that might be occurring when the command is entered, include the optional FORCE command.
mbos SHUTDOWN FORCE
The MainView Batch Optimizer Subsystem responds with messages to indicate that a forced shutdown might cause unpredictable results. You are given three options:
Option
Description
U
Continue with the forced shutdown
N
Switch to normal shutdown processing
The MainView Batch Optimizer Subsystem issues the BSL QUIESCE NOW command to perform an orderly shutdown.
Any other key
Stop the forced shutdown and continue processing as if the command had not been issued
This version of the documentation is no longer supported. However, the documentation is available for your convenience. You will not be able to leave comments.
Comments
Log in or register to comment.