Pipes operator command scope

The SCOPE command defines which Job Optimizer Pipes address spaces are affected by the operator commands. Job Optimizer Pipes can operate in either Local or Global mode.
  • Local mode - each system is handled independently. A command that is issued for a Job Optimizer Pipes address space affects only this address space.

  • Global mode - when operating in Global mode in a sysplex environment, a command might affect only the specific Job Optimizer Pipes address space in the system on which the command was issued (as in Local Mode) or it can be distributed to all of the Job Optimizer Pipes address spaces that are working in Global Mode in the sysplex.

Note

Several commands do not support the SCOPE parameter. These commands affect only the Job Optimizer Pipes address space for which the command was issued.

SCOPE parameter values

Value

Description

GLOBAL

Distribute the command to all Job Optimizer Pipes address spaces that are working in Global mode on all systems

GLOBAL is the default for all commands that support the SCOPE parameter except for SHUT. The SHUT command is executed only on the system on which it was issued unless SCOPE=GLOBAL is specified.

LOCAL

Perform the command only in the specific Job Optimizer Pipes address space on the system on which the command was issued