CDP worksheet for upgrades from 7.9.00 with RSSO to 7.9.01 with RSSO

You can upgrade the configuration distribution peer (CDP) after you upgrade or install the repository. If you are using an external Remedy Single Sign-On (Remedy SSO or RSSO) instance, it must already be installed.

You can upgrade the optional BMC Atrium Orchestrator Operator Control Panel (OCP), with the CDP. To upgrade  the OCP with the CDP, use the Operator Control Panel worksheet for upgrades from 7.9.00 with RSSO to 7.9.01 with RSSO worksheet with the CDP upgrade worksheet. 

Note

If you are installing a non-English version of the Operator Control Panel,  you must install it separately from the CDP. You must install the non-English OCP and CDP on separate Tomcat servers.

If you choose to modify any settings during the CDP upgrade, use this worksheet to record the new settings. The upgrade parameters in the table correspond to the parameters in the GUI upgrade panels and the options file.

Upgrade Feature Selection panel

Parameter

Default value and notes

Your value

Configuration Distribution Peer

Configuration Distribution Peer

 

Operator Control Panel

You can also select Operator Control Panel 

 

Root Directory Selection panel

Parameter

Default value and notes

Your value

Destination Directory

Click Browse to navigate to the directory where the CDP is installed.

 


Connection Details panel

Panel name and setting

Default value and notes

Your value

Web Server Host Name

Fully qualified domain name of the host where the CDP is installed.

Repository HA Address

Provide the repository IP address and port for communication with the enterprise service bus. Use the following format:

<IPaddress>:<port>

On a machine that has multiple network interface cards (NICs) this must be the IP address that allows access from the CDP and/or the HA-CDP.

The default port is the repository web port plus 10. For example, if the repository port is 28080, the Repository HA address is 28090.

Notes

  • This entry is required for installations/upgrades with embedded RSSO installations. This is not applicable if you are using external RSSO on the CDP.
  • Often multiple IP addresses are detected by the installer (on a machine that has multiple NICs). Verify the default address and port number and replace them if required.

 
CDP HA Address

Provide the CDP IP address and port for communication with the enterprise service bus. Use the following format:

<IPaddress>:<port>

On a machine that has multiple network interface cards (NICs) this must be an IP address that allows access from the repository and/or the HA-CDP.

The default port is the CDP web port plus 10. For example, if the CDP port is 38080, the CDP HA address is 38090.

Notes

  • This entry is required for installations/upgrades with embedded RSSO installations. This is not applicable if you are using external RSSO on the CDP.
  • Often multiple IP addresses are detected by the installer (on a machine that has multiple NICs). Verify the default address and port number and replace them if required.

 

CDP Server Auto Start panel

Parameter

Default value and notes

Your value

Do you want to start the server after the installation

Yes

 


Installation Choices Summary panel

Parameter

Default value and notes

Your value

Copy Text to Clipboard

Before you install/upgrade the CDP successfully, you can copy the peer connection details to a clipboard for further use.

 


Was this page helpful? Yes No Submitting... Thank you