Increasing the maximum number of active workflows


By default, the BMC Atrium Orchestrator Operator Control Panel application limits the number of active workflows to five. You can increase the maximum allowable active workflows by modifying the product configuration file.

To increase the maximum number of active workflows

  1. Using a text editor such as Notepad, open the ops-console-ui-config.xml file. 

    Warning

    Note

    This file is located on the CDP computer under
    [AO Home]/tomcat/webapps/baoocp.

  2. Modify the value listed in max-concurrent-processes. 

    <ops-console-ui-config>
        <max-concurrent-processes>*5*</max-concurrent-processes>
    </ops-console-ui-config> 
    Warning

    The macro unmigrated-inline-wiki-markup from Confluence is no longer available.

  3. Save and close the file. 

    Warning

    Note

    This change applies to all instances of BMC Atrium Orchestrator Operator Control Panel connected to the grid, and takes effect immediately.

 