Monitoring Object management operations for Microsoft System Center Operations Manager 2012
This topic describes the adapter requests and responses for the Monitoring Object operations.
Find Monitoring Object by ID operation
The Find Monitoring Object by ID operation retrieves the monitoring object that is identified by the specified globally unique identifier (GUID).
The following table describes the adapter request elements for the Find Monitoring Object operation.
Adapter request elements for the Find Monitoring Object operation
Element | Definition | Required |
---|---|---|
| Specifies the operation name: | Yes |
| Specifies the parent element for the command elements | Yes |
| Specifies the duration after which the operation times out | No |
| Specifies the parent element for the command parameters | Yes |
| Specifies the GUID of the monitoring object that you want to retrieve | Yes |
The following figure shows the <items>
XML for the Find Monitoring Object by ID operation.
<items>
XML for the Find Monitoring Object by ID operation
<items>
<item>
<timeout-secs>60</timeout-secs>
<command-parameters>
<monitoringobject-id>6c4bb046-82a8-ad78-0bc5-97aa4b8cc200</monitoringobject-id>
</command-parameters>
</item>
</items>
The following figure shows the sample adapter request.
Sample adapter request for the Find Monitoring Object by ID operation
<request-data>
<scom-request>
<operation-name>Get-SCOMClassInstance</operation-name>
<command-request>
<timeout-secs>120</timeout-secs>
<command-parameters>
<monitoringobject-id>4932d8f0-c8e2-2f4b-288e-3ed98a340b9f</monitoringobject-id>
</command-parameters>
</command-request>
</scom-request>
</request-data>
The following figure shows the adapter response.
Adapter response for the Find Monitoring Object by ID operation
<scom-response>
<metadata>
<status>success</status>
<count>1</count>
</metadata>
<commands-output>
<command-output>
<metadata>
<command> Import-Module OperationsManager; Get-SCOMClassInstance -id 4932d8f0-c8e2-2f4b-288e-3ed98a340b9f | format-list</command>
<execution-milliseconds>55631</execution-milliseconds>
<exit-code>0</exit-code>
<status>success</status>
<count>0</count>
</metadata>
<output>
<line>[Microsoft.SystemCenter.ManagementServicePool].IsDynamic : True</line>
<line>[Microsoft.SystemCenter.ManagementServicePool].MembershipVersion : 0</line>
<line>[Microsoft.SystemCenter.ManagementServicePool].UseDefaultObserver : True</line>
<line>[Microsoft.SystemCenter.ManagementServicePool].Description : (null)</line>
<line>[System.ConfigItem].ObjectStatus : System.Conf</line>
<line> igItem.Obje</line>
<line> ctStatusEnu</line>
<line> m.Active</line>
<line>[System.ConfigItem].AssetStatus : (null)</line>
<line>[System.ConfigItem].Notes : (null)</line>
<line>[System.Entity].DisplayName : All Managem</line>
<line> ent Servers</line>
<line> Resource P</line>
<line> ool</line>
<line>IsManaged : True</line>
<line>HealthState : Success</line>
<line>StateLastModified : 11/3/2016 1</line>
<line> 0:04:44 AM</line>
<line>IsAvailable : False</line>
<line>AvailabilityLastModified : 11/22/2016 </line>
<line> 7:53:08 AM</line>
<line>InMaintenanceMode : False</line>
<line>MaintenanceModeLastModified : </line>
<line>MonitoringClassIds :
{4932d8f0-c</line> <line> 8e2-2f4b-28</line> <line> 8e-3ed98a34</line> <line> 0b9f}</line>
<line>LeastDerivedNonAbstractMonitoringClassId : 4932d8f0-c8</line>
<line> e2-2f4b-288</line>
<line> e-3ed98a340</line>
<line> b9f</line>
<line>ManagementGroup : mgmt21145</line>
<line>Name : </line>
<line>Path : </line>
<line>DisplayName : All Managem</line>
<line> ent Servers</line>
<line> Resource P</line>
<line> ool</line>
<line>FullName : Microsoft.S</line>
<line> ystemCenter</line>
<line> .AllManagem</line>
<line> entServersP</line>
<line> ool</line>
<line>ManagementPackClassIds : {4932d8f0-c</line> <line> 8e2-2f4b-28</line> <line> 8e-3ed98a34</line> <line> 0b9f}
</line>
<line>LeastDerivedNonAbstractManagementPackClassId : 4932d8f0-c8</line>
<line> e2-2f4b-288</line>
<line> e-3ed98a340</line>
<line> b9f</line>
<line>TimeAdded : 2/27/2016 1</line>
<line> 0:51:03 AM</line>
<line>LastModifiedBy : b767979e-de</line>
<line> 47-4264-913</line>
<line> 4-816a1b714</line>
<line> 1ad</line>
<line>Values :
{True, 0, T</line> <line> rue, (null)</line> <line> ...}
</line>
<line>LastModified : 11/22/2016 </line>
<line> 5:10:13 AM</line>
<line>IsNew : False</line>
<line>HasChanges : False</line>
<line>Id : 4932d8f0-c8</line>
<line> e2-2f4b-288</line>
<line> e-3ed98a340</line>
<line> b9f</line>
<line>ManagementGroupId : 1640cc66-2f</line>
<line> a5-1ffb-33e</line>
<line> e-231fa5a10</line>
<line> cb8</line>
</output>
</command-output>
</commands-output>
</scom-response>
Find Monitoring Objects operation
The Find Monitoring Objects operation retrieves the details of all the monitoring objects associated with the management server.
The following table describes the adapter request elements for the Find Monitoring Objects operation.
Adapter request elements for the operation
lement | Definition | Required |
---|---|---|
| Specifies the operation name: | Yes |
| Specifies the parent element for the command elements | Yes |
| Specifies the duration after which the operation times out | No |
| Specifies the parent element for the command parameters | Yes |
The following figure shows the <items>
XML for the Find Monitoring Objects operation.
<items>
XML for the Find Monitoring Object operation
<items>
<item>
<timeout-secs>120</timeout-secs>
<command-parameters/>
</item>
</items>
The following figure shows the sample adapter request.
Sample adapter request for the Find Monitoring Objects operation
<request-data>
<scom-request>
<operation-name>Get-SCOMClassInstance</operation-name>
<command-request>
<timeout-secs>120</timeout-secs>
<command-parameters />
</command-request>
</scom-request>
</request-data>
The following figure shows the adapter response.
Adapter response for the Find Monitoring Objects operation
<scom-response>
<metadata>
<status>success</status>
<count>1</count>
</metadata>
<commands-output>
<command-output>
<metadata>
<command> Import-Module OperationsManager; Get-SCOMClassInstance | format-list</command>
<execution-milliseconds>120016</execution-milliseconds>
<exit-code>9999</exit-code>
<status>success</status>
<count>0</count>
</metadata>
<output>
<line>Attempting to connect to remote host...</line>
<line>Initialising rctrlx server component...</line>
<line>Executing remote application: cmd /c "echo . | powershell -Version 1.0 -NonInteractive -Command Import-Module OperationsManager; Get-SCOMClassInstance ^| format-list "</line>
<line>Stdout:</line>
<line>[Microsoft.SystemCenter.ManagedComputer].InstallDirectory : C:\Program Files</line>
<line> \Microsoft Syste</line>
<line> m Center 2012 R2</line>
<line> \Operations Mana</line>
<line> ger\Server\</line>
<line>[Microsoft.Windows.Server.Computer].IsVirtualNode : (null)</line>
<line>[Microsoft.Windows.Computer].PrincipalName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].DNSName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].NetbiosComputerName : clm-pun-021145</line>
<line>[Microsoft.Windows.Computer].NetbiosDomainName : VMW28RDS1561DC</line>
<line>[Microsoft.Windows.Computer].IPAddress : 10.133.27.14, 10</line>
<line> .133.80.45</line>
<line>[Microsoft.Windows.Computer].NetworkName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].ActiveDirectoryObjectSid : (null)</line>
<line>[Microsoft.Windows.Computer].IsVirtualMachine : (null)</line>
<line>[Microsoft.Windows.Computer].DomainDnsName : vmw28rds1561dc.l</line>
<line> ocal</line>
<line>[Microsoft.Windows.Computer].OrganizationalUnit : CN=Computers,DC=</line>
<line> vmw28rds1561dc,D</line>
<line> C=local</line>
<line>[Microsoft.Windows.Computer].ForestDnsName : vmw28rds1561dc.l</line>
<line> ocal</line>
<line>[Microsoft.Windows.Computer].ActiveDirectorySite : Default-First-Si</line>
<line> te-Name</line>
<line>[Microsoft.Windows.Computer].LogicalProcessors : 2</line>
<line>[Microsoft.Windows.Computer].PhysicalProcessors : 2</line>
<line>[Microsoft.Windows.Computer].HostServerName : (null)</line>
<line>[Microsoft.Windows.Computer].VirtualMachineName : (null)</line>
<line>[Microsoft.Windows.Computer].OffsetInMinuteFromGreenwichTime : (null)</line>
<line>[Microsoft.Windows.Computer].LastInventoryDate : (null)</line>
<line>[Microsoft.Windows.Server.6.2.Computer].InstallType : Full</line>
<line>[System.ConfigItem].ObjectStatus : System.ConfigIte</line>
<line> m.ObjectStatusEn</line>
<line> um.Active</line>
<line>[System.ConfigItem].AssetStatus : (null)</line>
<line>[System.ConfigItem].Notes : (null)</line>
<line>[System.Entity].DisplayName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>IsManaged : True</line>
<line>HealthState : Warning</line>
<line>StateLastModified : 11/11/2016 8:17:</line>
<line> 20 PM</line>
<line>IsAvailable : False</line>
<line>AvailabilityLastModified : 12/2/2016 7:49:4</line>
<line> 5 AM</line>
<line>InMaintenanceMode : False</line>
<line>MaintenanceModeLastModified : </line>
<line>MonitoringClassIds :
{6fec7139-239b-3</line> <line> c49-6476-ec5e47e</line> <line> 7101a, 8c897064-</line> <line> 719b-6be5-3046-7</line> <line> 81a82171d58, e1a</line> <line> e9104-c9a3-467f-</line> <line> adba-33f801db7d3</line> <line> 7, 44ab701b-5da9</line> <line> -ca21-a94b-8b828</line> <line> 28a69d8...}</line>
<line>LeastDerivedNonAbstractMonitoringClassId : ea99500d-8d52-fc</line>
<line> 52-b5a5-10dcd1e9</line>
<line> d2bd</line>
<line>ManagementGroup : mgmt21145</line>
<line>Name : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>Path : </line>
<line>DisplayName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>FullName : Microsoft.Window</line>
<line> s.Computer:clm-p</line>
<line> un-021145.vmw28r</line>
<line> ds1561dc.local</line>
<line>ManagementPackClassIds : {6fec7139-239b-3</line> <line> c49-6476-ec5e47e</line> <line> 7101a, 8c897064-</line> <line> 719b-6be5-3046-7</line> <line> 81a82171d58, e1a</line> <line> e9104-c9a3-467f-</line> <line> adba-33f801db7d3</line> <line> 7, 44ab701b-5da9</line> <line> -ca21-a94b-8b828</line> <line> 28a69d8...}
</line>
<line>LeastDerivedNonAbstractManagementPackClassId : ea99500d-8d52-fc</line>
<line> 52-b5a5-10dcd1e9</line>
<line> d2bd</line>
<line>TimeAdded : 2/27/2016 11:02:</line>
<line> 35 AM</line>
<line>LastModifiedBy : </line>
<line>Values :
{C:\Program File</line> <line> s\Microsoft Syst</line> <line> em Center 2012 R</line> <line> 2\Operations Man</line> <line> ager\Server\, (n</line> <line> ull), clm-pun-02</line> <line> 1145.vmw28rds156</line> <line> 1dc.local, clm-p</line> <line> un-021145.vmw28r</line> <line> ds1561dc.local..</line> <line> .}
</line>
<line>LastModified : 10/19/2016 10:43</line>
<line> :34 AM</line>
<line>IsNew : False</line>
<line>HasChanges : False</line>
<line>Id : 9f1c5d29-a352-e4</line>
<line> 25-250b-e2e351b1</line>
<line> 70e7</line>
<line>ManagementGroupId : 1640cc66-2fa5-1f</line>
<line> fb-33ee-231fa5a1</line>
<line> 0cb8</line>
<line>[System.ExtensionType].Identity : Target,3|||EnumerationValue||,3|</line>
<line> ||RelationshipEndPointType||</line>
<line>[System.ExtensionType].RootIdentity : 3|||RelationshipEndPointType||</line>
<line>[System.ExtensionType].BaseIdentity : (null)</line>
<line>[System.ExtensionType].ParentIdentity : 3|||RelationshipEndPointType||</line>
<line>[System.ExtensionType].FieldName : Target</line>
<line>[System.ExtensionType].FieldOrder : 1</line>
<line>[System.ExtensionType].Metadata : EnumerationTarget|Microsoft.Syst</line>
<line> emCenter.RelationshipEndPointTyp</line>
<line> e.Target, Microsoft.SystemCenter</line>
<line> .Datawarehouse.OLAP.Base, Public</line>
<line> KeyToken=31bf3856ad364e35;</line>
<line>[System.ExtensionType].FieldType : 3|||EnumerationValue||</line>
<line>[System.Entity].DisplayName : Target</line>
<line>IsManaged : True</line>
<line>HealthState : Uninitialized</line>
<line>StateLastModified : </line>
<line>IsAvailable : False</line>
<line>AvailabilityLastModified : 11/22/2016 7:53:08 AM</line>
<line>InMaintenanceMode : False</line>
<line>MaintenanceModeLastModified : </line>
<line>MonitoringClassIds :
{b96d8028-9334-81e6-9ba9-641b20d</line> <line> e3c86}</line>
<line>LeastDerivedNonAbstractMonitoringClassId : b96d8028-9334-81e6-9ba9-641b20de</line>
<line> 3c86</line>
<line>ManagementGroup : mgmt21145</line>
<line>Name : Target,3|||EnumerationValue||,3|</line>
<line> ||RelationshipEndPointType||</line>
<line>Path : </line>
<line>DisplayName : Target</line>
<line>FullName : System.ExtensionType:Target,3|||</line>
<line> EnumerationValue||,3|||Relations</line>
<line> hipEndPointType||</line>
<line>ManagementPackClassIds : {b96d8028-9334-81e6-9ba9-641b20d</line> <line> e3c86}
</line>
<line>LeastDerivedNonAbstractManagementPackClassId : b96d8028-9334-81e6-9ba9-641b20de</line>
<line> 3c86</line>
<line>TimeAdded : 2/27/2016 10:59:57 AM</line>
<line>LastModifiedBy : 7431e155-3d9e-4724-895e-c03ba951</line>
<line> a352</line>
<line>Values :
{Target,3|||EnumerationValue||,3</line> <line> |||RelationshipEndPointType||, 3</line> <line> |||RelationshipEndPointType||, (</line> <line> null), 3|||RelationshipEndPointT</line> <line> ype||...}
</line>
<line>LastModified : 2/27/2016 10:59:57 AM</line>
</output>
</command-output>
</commands-output>
</scom-response>
Find Monitoring Object operation by Class operation
The Find Monitoring Object by Class operation
The following table describes the adapter request elements for the Find Monitoring Object by Class operation.
Adapter request elements for the Find Monitoring Object by Class operation
Element | Definition | Required |
---|---|---|
| Specifies the operation name: | Yes |
| Specifies the parent element for the command elements | Yes |
| Specifies the duration after which the operation times out | No |
| Specifies the parent element for the command parameters | Yes |
| Specifies the parent element for the | Yes |
| Specifies the globally unique identifier (GUID) of the monitoring class | Yes |
The following figure shows the <items>
XML for the operation.
<items>
XML for the Find Monitoring Object operation
<items>
<item>
<timeout-secs>120</timeout-secs>
<command-parameters>
<monitoringclass>
<monitoringclass-id>e1ae9104-c9a3-467f-adba-33f801db7d37</monitoringclass-id>
</monitoringclass>
</command-parameters>
</item>
</items>
The following figure shows the sample adapter request.
Sample adapter request for the Find Monitoring Object by Class operation
<request-data>
<scom-request>
<operation-name>Get-SCOMClassInstance</operation-name>
<command-request>
<timeout-secs>120</timeout-secs>
<command-parameters>
<monitoringclass>
<monitoringclass-id>e1ae9104-c9a3-467f-adba-33f801db7d37</monitoringclass-id>
</monitoringclass>
</command-parameters>
</command-request>
</scom-request>
</request-data>
The following figure shows the adapter response.
Adapter response for the Find Monitoring Object by Class operation
<scom-response>
<metadata>
<status>success</status>
<count>1</count>
</metadata>
<commands-output>
<command-output>
<metadata>
<command> Import-Module OperationsManager; Get-SCOMClassInstance -class (Get-SCOMClass -id e1ae9104-c9a3-467f-adba-33f801db7d37) | format-list</command>
<execution-milliseconds>120015</execution-milliseconds>
<exit-code>9999</exit-code>
<status>success</status>
<count>0</count>
</metadata>
<output>
<line>Attempting to connect to remote host...</line>
<line>Initialising rctrlx server component...</line>
<line>Executing remote application: cmd /c "echo . | powershell -Version 1.0 -NonInteractive -Command Import-Module OperationsManager; Get-SCOMClassInstance -class (Get-SCOMClass -id e1ae9104-c9a3-467f-adba-33f801db7d37) ^| format-list "</line>
<line>Stdout:</line>
<line>[Microsoft.Windows.Server.Computer].IsVirtualNode : (null)</line>
<line>[Microsoft.Windows.Computer].PrincipalName : vm-w28-rds1561.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].DNSName : vm-w28-rds1561.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].NetbiosComputerName : vm-w28-rds1561</line>
<line>[Microsoft.Windows.Computer].NetbiosDomainName : VMW28RDS1561DC</line>
<line>[Microsoft.Windows.Computer].IPAddress : 10.129.49.27</line>
<line>[Microsoft.Windows.Computer].NetworkName : vm-w28-rds1561.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].ActiveDirectoryObjectSid : S-1-5-21-4182199</line>
<line> 736-670652207-38</line>
<line> 57655355-1003</line>
<line>[Microsoft.Windows.Computer].IsVirtualMachine : (null)</line>
<line>[Microsoft.Windows.Computer].DomainDnsName : vmw28rds1561dc.l</line>
<line> ocal</line>
<line>[Microsoft.Windows.Computer].OrganizationalUnit : OU=Domain Contro</line>
<line> llers,DC=vmw28rd</line>
<line> s1561dc,DC=local</line>
<line>[Microsoft.Windows.Computer].ForestDnsName : vmw28rds1561dc.l</line>
<line> ocal</line>
<line>[Microsoft.Windows.Computer].ActiveDirectorySite : Default-First-Si</line>
<line> te-Name</line>
<line>[Microsoft.Windows.Computer].LogicalProcessors : 2</line>
<line>[Microsoft.Windows.Computer].PhysicalProcessors : 2</line>
<line>[Microsoft.Windows.Computer].HostServerName : (null)</line>
<line>[Microsoft.Windows.Computer].VirtualMachineName : (null)</line>
<line>[Microsoft.Windows.Computer].OffsetInMinuteFromGreenwichTime : (null)</line>
<line>[Microsoft.Windows.Computer].LastInventoryDate : (null)</line>
<line>[Microsoft.SystemCenter.ManagedComputer].InstallDirectory : C:\Program Files</line>
<line> \Microsoft Monit</line>
<line> oring Agent\Agen</line>
<line> t\</line>
<line>[Microsoft.Windows.Server.2008.Computer].InstallType : Full</line>
<line>[System.ConfigItem].ObjectStatus : System.ConfigIte</line>
<line> m.ObjectStatusEn</line>
<line> um.Active</line>
<line>[System.ConfigItem].AssetStatus : (null)</line>
<line>[System.ConfigItem].Notes : (null)</line>
<line>[System.Entity].DisplayName : vm-w28-rds1561.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>IsManaged : True</line>
<line>HealthState : Success</line>
<line>StateLastModified : 11/11/2016 7:48:</line>
<line> 07 AM</line>
<line>IsAvailable : True</line>
<line>AvailabilityLastModified : 11/22/2016 6:03:</line>
<line> 23 AM</line>
<line>InMaintenanceMode : False</line>
<line>MaintenanceModeLastModified : 11/22/2016 9:54:</line>
<line> 22 AM</line>
<line>MonitoringClassIds :
{e817d034-02e8-2</line> <line> 94c-3509-01ca254</line> <line> 81689, ea99500d-</line> <line> 8d52-fc52-b5a5-1</line> <line> 0dcd1e9d2bd, bcc</line> <line> 71e62-c387-70de-</line> <line> f8d6-2fb1c3f5a57</line> <line> 2, e1ae9104-c9a3</line> <line> -467f-adba-33f80</line> <line> 1db7d37...}</line>
<line>LeastDerivedNonAbstractMonitoringClassId : ea99500d-8d52-fc</line>
<line> 52-b5a5-10dcd1e9</line>
<line> d2bd</line>
<line>ManagementGroup : mgmt21145</line>
<line>Name : vm-w28-rds1561.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>Path : </line>
<line>DisplayName : vm-w28-rds1561.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>FullName : Microsoft.Window</line>
<line> s.Computer:vm-w2</line>
<line> 8-rds1561.vmw28r</line>
<line> ds1561dc.local</line>
<line>ManagementPackClassIds : {e817d034-02e8-2</line> <line> 94c-3509-01ca254</line> <line> 81689, ea99500d-</line> <line> 8d52-fc52-b5a5-1</line> <line> 0dcd1e9d2bd, bcc</line> <line> 71e62-c387-70de-</line> <line> f8d6-2fb1c3f5a57</line> <line> 2, e1ae9104-c9a3</line> <line> -467f-adba-33f80</line> <line> 1db7d37...}
</line>
<line>LeastDerivedNonAbstractManagementPackClassId : ea99500d-8d52-fc</line>
<line> 52-b5a5-10dcd1e9</line>
<line> d2bd</line>
<line>TimeAdded : 2/27/2016 12:29:</line>
<line> 39 PM</line>
<line>LastModifiedBy : </line>
<line>Values :
{(null), vm-w28-</line> <line> rds1561.vmw28rds</line> <line> 1561dc.local, vm</line> <line> -w28-rds1561.vmw</line> <line> 28rds1561dc.loca</line> <line> l, vm-w28-rds156</line> <line> 1...}
</line>
<line>LastModified : 11/11/2016 8:30:</line>
<line> 01 AM</line>
<line>IsNew : False</line>
<line>HasChanges : False</line>
<line>Id : 79b40649-34f8-15</line>
<line> cd-ea32-b9d44818</line>
<line> 0f2a</line>
<line>ManagementGroupId : 1640cc66-2fa5-1f</line>
<line> fb-33ee-231fa5a1</line>
<line> 0cb8</line>
<line>[Microsoft.Windows.Server.Computer].IsVirtualNode : (null)</line>
<line>[Microsoft.Windows.Computer].PrincipalName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].DNSName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].NetbiosComputerName : clm-pun-021145</line>
<line>[Microsoft.Windows.Computer].NetbiosDomainName : VMW28RDS1561DC</line>
<line>[Microsoft.Windows.Computer].IPAddress : 10.133.27.14, 10</line>
<line> .133.80.45</line>
<line>[Microsoft.Windows.Computer].NetworkName : clm-pun-021145.v</line>
<line> mw28rds1561dc.lo</line>
<line> cal</line>
<line>[Microsoft.Windows.Computer].ActiveDirectoryObjectSid : (null)</line>
<line>[Microsoft.Windows.Computer].IsVirtualMachine : (null)</line>
<line>[Microsoft.Windows.Computer].DomainDnsName : vmw28rds1561dc.l</line>
<line> ocal</line>
<line>[Microsoft.Windows.Computer].OrganizationalUnit : CN=Computers,DC=</line>
<line> vmw28rds1561dc,D</line>
<line> C=local</line>
<line>[Microsoft.Windows.Computer].ForestDnsName : vmw28rds1561dc.l</line>
<line> ocal</line>
<line>[Microsoft.Windows.Computer].ActiveDirectorySite : Default-First-Si</line>
<line> te-Name</line>
<line>[Microsoft.Windows.Computer].LogicalProcessors : 2</line>
<line>[Microsoft.Windows.Computer].PhysicalProcessors : 2</line>
<line>[Microsoft.Windows.Computer].HostServerName : (null)</line>
<line>[Microsoft.Windows.Computer].VirtualMachineName : (null)</line>
<line>[Microsoft.Windows.Computer].OffsetInMinuteFromGreenwichTime : (null)</line>
<line>[Microsoft.Windows.Computer].LastInventoryDate : (null)</line>
<line>[Microsoft.Windows.Server.6.2.Computer].InstallType : Full</line>
<line>[Microsoft.SystemCenter.ManagedComputer].InstallDirectory : C:\Program Files</line>
<line> \Microsoft Syste</line>
<line> m Center 2012 R2</line>
<line> \Operations Mana</line>
<line> ger\Server\</line>
<line>[System.ConfigItem].ObjectStatus : System.ConfigIte</line>
<line> m.ObjectStatusEn</line>
<line> um.Active</line>
<line>[System.ConfigItem].AssetStatus : (null)</line>
<line>[System.ConfigItem].Notes : (null)</line>
<line>[System.Entity].DisplayName : clm-pun-021145.v</line>
</output>
</command-output>
</commands-output>
</scom-response>
Comments
Log in or register to comment.