Update Power Configuration

Changes settings of the specified power scheme.

Workflow inputs – Update Power Configuration

Call Workflow Input

Description

Required?

Default Value

connection details

XML document conforming to the ConnectionDetails common object that contains the information required to execute a command.

Yes

n/a

schema name

The power scheme to be created. This scheme will be created with the properties of the currently active scheme.

Yes

n/a

monitor timeout ac

Turns the monitor off after the specified number of minutes when the system is operating on AC Power. A value of 0 will disable the time–out.

No

n/a

monitor timeout dc

Turns the monitor off after the specified number of minutes when the system is operating on DC (battery) power. A value of 0 will disable the time–out.

No

n/a

disk timeout ac

Turns the hard disks off after the specified number of minutes when the system is operating on AC power. A value of 0 will disable the time–out.

No

n/a

disk timeout dc

Turns the hard disks off after the specified number of minutes when the system is operating on DC (battery) power. A value of 0 will disable the time–out.

No

n/a

standby timeout ac

Puts the computer in standby mode after the specified number of minutes when the system is operating on AC power. A value of 0 will disable the time–out.

No

n/a

standby timeout dc

Puts the computer in standby mode after the specified number of minutes when the system is operating on DC (battery) power. A value of 0 will disable the time–out.

No

n/a

hibernate timeout ac

Saves the contents of the computer's memory to disk and turns off the computer after the specified number of minutes when the system is operating on AC power. A value of 0 will disable the time–out.

No

n/a

hibernate timeout dc

Saves the contents of the computer's memory to disk and turns off the computer after the specified number of minutes when the system is operating on DC (battery) power. A value of 0 will disable the time–out.

No

n/a

processor throttle ac

Selects the dynamic throttling policy to be used, if your microprocessor supports processor performance state controls, when the system is operating on AC power.

 

Valid values:

none – Causes the microprocessor to operate at the highest performance state at all times.

 

constant – Causes the microprocessor to operate at the lowest performance state at all times.

 

degrade – Causes the microprocessor to operate at the lowest performance state, and further reduces performance by applying stop clock throttling as the system battery drains.

 

adaptive – Modifies the performance state dynamically based on the demand the system puts on the microprocessor.

No

n/a

processor throttle dc

Selects the dynamic throttling policy to be used, if your microprocessor supports processor performance state controls, when the system is operating on DC power.

 

Valid values:

none – Causes the microprocessor to operate at the highest performance state at all times.

 

constant – Causes the microprocessor to operate at the lowest performance state at all times.

 

degrade – Causes the microprocessor to operate at the lowest performance state, and further reduces performance by applying stop clock throttling as the system battery drains.

 

adaptive – Modifies the performance state dynamically based on the demand the system puts on the microprocessor.

No

n/a

 

Workflow outputs – Update Power Configuration

Call Workflow Output

Description

output

XML document consisting of one or more <line> elements that contain the command response. Each <line> element contains an index attribute indicating the order in which the information was returned by the command.

success

Did the operation succeed?

 

Valid values: true, false

 