Troubleshooting the BPPM adapter
This topic provides information for troubleshooting issues specific to the BMC Atrium Orchestrator application adapter for BMC ProactiveNet Performanance Management.
Message: Event with WARNING severity received by the BMC Atrium Orchestrator Monitor Adapter for BMC ProactiveNet Performanance Management but slot severity in event is not received.
Explanation: WARNING is the default severity value in the BMC ProactiveNet Performanance Management application.
User response: To resolve this issue, you must add a configuration parameter to the gateway.imcomm file as follows:
- Access the computer on which BMC ProactiveNet Performanance Management is installed and navigate to the installHome\pw\server\etc directory.
- Open the gateway.imcomm file and then add
cond=always
. - Restart the BMC ProactiveNet Performanance Management service.
Message: Unable to monitor events from the admin or any other cell.
User response: Perform the following steps:
- (optional) Remove the following line from the mcell.conf file located in $ MCELL_HOME \pw\server\etc\<cellName>:
<serverDirectoryName>=C:\Program Files\ProactiveNet\pw\pronto\data\admin\admin.dir - Recompile the cell.
- Restart the cell.
Comments
Log in or register to comment.